Copeland scroll compressor nomenclature. For additional information on this product, please .


Copeland scroll compressor nomenclature The 6-to-15-ton Copeland Scroll compressors do not have internal pressure relief valves. High Pressure Control A high pressure cut-out control must be used in all applications. There are a few important differences outlined below that must be observed when designing a system with the Copeland Scroll UltraTech two step compressor. • Allow time for the compressor to cool before servicing. Securely fasten the protective terminal cover or molded plug to the compressor, and 2. Nomenclature The Copeland Scroll Digital compressor model numbers are designated by a D in the third character, ZBD30KCE-TFD. Copeland Scroll™ variable speed compressor in a safe and reliable manner. 4-1299 Application Guidelines for Copeland Scroll Compressors 2 - 6 Horsepower 4-1327 Economized Vapor Injection (EVI) Compressors 4-1387 Application Guidelines for ZS**KAE Copeland Scroll™ Refrigeration Compressors 1. Large Commercial Compressors Our Copeland Scroll™ commercial compressors offer the most advanced scroll technology available to support your commercial air-conditioning needs, including: Widest R-410A selection available Model ranges from 2 - 60 HP in singles Tandems up to 80 HP Copeland Scroll™ ZPK5 R-410A Compressor Cross Reference Guide Code H-Phase-Volts PFV 60-1-208/230 PF 60-1-265 TF5 60-3-200/230 TFD 60-3-460 TFE 60-3-55 TF 60-3-380 UltraTech™ Copeland™ ZPSK5 UltraTech™ Single Phase Compressor Models Copeland™ ZPSK5 UltraTech™ Three Phase Compressor Models Tonnage ZPSK5 Preferred Wholesale Model ZPSK4 2T May 19, 2014 · Copeland Scroll refrigeration compressors (such as ZBxxKA-PFV) are designated by a "Z" in the first position of the model number. The 6 to 15 ton Copeland Scroll compressors do not have internal pressure relief valves. Refrigeration Type : R410A Cooling Efficiency (EER) : 9. Whether it’s a single-circuit packaged system or a multi- AE4-1331 The digital scroll compressor unloads by taking ZPD34-ZPD54K5 AE4-1365 ZPD61-ZPD83KC, ZPD91KC, ZPD104KCE, ZPD122KCE AE4-1303 ZPD103KC, ZPD120KC, ZPD137-182KC, ZRD94-125KC AE4-1312 ZRD36-81KC Nomenclature The model number of the Copeland Scroll Digital compressors includes the approximate nominal The ZPS*K7 two-stage modulated Copeland Scroll™ compressors are ideally suited for residential and light commercial applications where a capacity stage reduction and part-load efficiency are desired. C7. 5 HP 5-1377 Copeland Scroll Outdoor Condensing Unit 5-1412 Copeland Scroll Outdoor Refrigeration Unit 2. Due to this Copeland Scroll compressor are described in Figure 9 at the end of this bulletin. Nomenclature 2. ' Product Description ZPV066 and ZPV096 variable speed compressors are Jan 5, 2021 · A44 –1331 – ZP16 to ZP44K3E and ZP14 to ZP61K5E R-410A 1. For additional The 70 frame ZP*K3 and ZP*KC Copeland scroll compressors are designed for a wide variety of light commercial cooling and heat pump applications. 0 ZR R407C Series Compressor; Copeland Scroll 4-7 HP ZBHKJ; Copeland Scroll ZP25KSE PFZ. 5 to 15 HP). It is the most efficient and durable compressor Emerson has ever developed for air-conditioning and refrigeration. Number –230 indicates a standard compressor B/M and model number. %PDF-1. 1kW) cooling capacity at the AHRI high Copeland Scroll variable speed compressors represent the pinnacle of reliability through enhancements such as: • Active protection algorithms: provided by the motor control drive • Robust scroll design: Outstanding reliability over competing compression technology • Proven in-field performance: Over 25 years of scroll The Scroll compressor has been under development at Emerson Climate Technologies since 1979. The ZPS*K7 compressor family is ZSVH Copeland Scroll™ variable speed compressor in a safe and reliable manner. Copeland Scroll ZR24KRE compressor pdf manual download. Include the Copeland Scroll Digital compressor in your product offering today. Due R410A Copeland Scroll Compressors • AE4-1331 ZP16 to ZP44K3E and ZP14 to ZP61K5E R410a 1/5 to 5 Ton Copeland Scroll Compressors • AE4-1303 7 to 15 Ton ZR*KC and ZP*KC Copeland Scroll Compressors • AE4-1388 20-40 Ton ZP*KC and ZR*KC Copeland Scroll Compressors Compressor assemblies in multiple arrangements are Copeland Scroll variable speed compressor capacities Model Displacement Tonnage 0. 1. 208-230Volt 1ph R-22. 0 ZPV 021 028 034 038 041 ZHV 021 034 ZHV models for hot water heating applications. For additional bulletins and compressor information, please refer to Copeland Online Product Information (OPI). YBD*K1E compressors are intended for installation in systems in accordance with the following directives and regulations: Copeland Scroll variable speed compressor nomenclature Z P V 066 2 E- 7 E 9- XXX Z = Scroll Variable speed drive nomenclature E V C 115 0 B- K 1- XXX E Replacing a 20-year-old scroll platform, the Copeland ZPKZ Fixed Speed Scroll Compressor is designed for industry-leading efficiency and reliability and is suitable for a wide array of commercial applications including rooftops, splits, chillers and reversible systems. These application guidelines deal with vertical single Copeland Scroll compressors • Allow time for the compressor to cool before servicing. T Reciprocating Compressors . In terms of mechanical strength, ZO scroll compressors benefit from many years of experience with R-410A air-conditioning compressors, which operate at similar pressure levels as CO 2 compressors. Aug 31, 2017 · Nomenclature Copeland Scroll tandem compressor units Published 08/31/2017 03:14 PM | Updated 12/20/2021 06:07 PM Are you confused by the nomenclature when dealing with Copeland Scroll tandem compressor units? 1 Scroll nomenclature The scroll nomenclature, as given on the nameplate of the compressor, contains information such as compressor model family, application, capacity and other specifications. Multiple compressors are connected with a manifold, commonly referred to as tandems or trios. Nomenclature The model numbers of the Copeland scroll compressors include the approximate nominal cooling capacity operating at 60 Hz at standard operating conditions. An example would be the YA31K1E-PFV, which has 31,000 Btu/hr (9. - Ensure that materials and wiring do not touch high temperature areas of the compressor. 1°C), Copeland Scroll™ variable speed compressor in a safe and reliable manner. 2. The centre letter "F" (eg, TFD) stands for inherent motor protector (Klixon) which is embedded in the stator head and interrupts the power supply of the windings internally at high current or high Copeland Scroll compressor are described in Figure 1. T Copeland Scroll™ variable speed compressor in a safe and reliable manner. An example would be the ZP236KCE-TED, which has 236,000 Btu/hr (69. The ZP*K6 compressors include a number of features outlined in the table below. ' Product Description The ZPV063 variable speed compressor has a speed range of 1000 (refer to operating envelope for low • All Copeland Scroll compressors are designed with a discharge check valve that isolates the high pressure discharge gas. 0 compressor UL recognition and may increase the risk of malfunction and serious injury or death High Pressure Control A high-pressure cut-out control must be used in all applications. When the solenoid valve is energized the compressor is in full-load and when de-energized the compressor is in part-load. It is the most efficient and durable compressor Emerson Climate Technologies has ever developed for air-conditioning and refrigeration. When the solenoid is energized in the • The Copeland Scroll compressor design has several inherent reliability advantages: • Redesigned suction gas flow results in lower oil circulation and better motor cooling. 3. Figure 1: Next Generation CoreSense module on Stream compressor 2 Nomenclature Copeland Scroll compressor nomenclature ZP D 42K 5 E– T F D –130 Z scroll family series AC, R-410A D = Digital S = UltraTech Copeland Scroll variable speed compressor nomenclature Z Z= Scroll Family V = Variable Speed Technology Cubic Centimeters of Displacement Per Revolution (3 Numeric Characters) Model Variation Motor Type E = Enhanced External Protection X= Protection Not Specified Bill of Material Variation Code Variable speed drive nomenclature E V = Variable expertise and 25 years of leadership in scroll technology. The ZPD34-ZPD54K5, ZPD61-ZPD83KC, ZPD91KC, ZPD104KCE, ZPD122KCE, and ZRD36-81KC compressors described in this bulletin use a lift piston 2. The following overview shows an example of the structure of the nomenclature for a fixed-speed scroll compressor. 1 Scroll nomenclature The scroll nomenclature, as given on the nameplate of the compressor, contains information such as compressor model family, application, capacity and other specifications. Smart and versatile Copeland Scroll Fusion was crafted specifically to adhere These models of Copeland Scroll compressors do not have internal pressure relief valves. ZR34K3 PFJ Airconditioning. 5 to 5 Ton Copeland Scroll™ Compressors; AE4 – 1365 – 5 to 12 Ton ZP*K3, ZP*KC, and ZP*KW R-410A Copeland Scroll™ Compressors for Air Conditioning; AE4 – 1303 – 7 to 15 Ton ZR*KC and ZP*KC Copeland Scroll™ Compressors; 17:23 – Charge limits and crankcase heater The model designation contains the following technical information about the compressors: Figure 1: Nomenclature 2. 1. The ZP*KW Copeland Scroll compressors are designed primarily for swimming pool heating and cooling. For more information, click here: https://goo. The ZPS*K7 is based upon the ZP*K7 fixed capacity scroll compressor (reference AE4-1481). All Copeland Scroll compressors are designed so that the compression elements can separate axially a few thousands of an inch. Copeland Scroll variable speed compressors provide efficient and reliable heating performance at temperatures as low as -25°C. Remove refrigerant from both the high and low side of the compressor. Particular emphasis has been placed on the user’s safety. Copeland Tandem and Trio Scroll™ compressors make it possible for greater flexibility in system design for a wide The model designation contains the following technical information about the compressors: Figure 1: Nomenclature 2. • EVI CoreSense™ Control kits provide advanced features to ensure optimum system operation. The scroll compressors outlined in this bulletin range in size from 14,650 Btu/hr to 53,500 Btu/hr (4. This new range of compressors features a significant size, weight, and sound reduction in all models. 5 to 5 Ton Copeland Scroll™ Compressors AE4-1331 R7 July 2015 scroll elements during the loaded and unloaded modes of operation are shown in Figures 6 and 7 at the end of this bulletin. compressors, and bulletins AE4-1331 and AE4-1365 for ZPS*K4 compressors. 1 AE4-1331 R7 ZP16 to ZP44K3E and ZP14 to ZP61K5E R-410A 1. Also for: Copeland scroll zr92kre, Copeland scroll zr28kre, Copeland scroll zr48kre, ZR R407C Series Compressor; Copeland Scroll 4-7 HP ZBHKJ; Copeland Scroll ZP122KCE TFD. compressors lie in the high pressure levels, the higher mass flow for a given displacement, and designing for proper lubrication. See Table 1 for a summary of mechanical specifications. Nomenclature The model numbers of Copeland Scroll compressors include the approximate nominal 60 Hz capacity at standard operating conditions. In either case the module M1-M2 contacts are opened if the internal discharge temperature exceeds safe limits. 1 Common information about Copeland Scroll™ compressors The Scroll compressor has been under development at Emerson since 1979. • Keep all non-essential personnel away from the compressor during service. Nomenclature The model number of the Copeland Scroll Digital compressors includes the approximate nominal 60 Hz capacity at the AHRI high temperature full load air ™• Gama de compresores Copeland Scroll ZR para R513A, R407C y R134a • Gama de compresores Copeland Scroll YP para R32 • Gama de compresores Copeland Scroll ZP para R410A • Gamas de compresores Copeland Scroll ZPD y ZRD digitales para R513A, R410A y R407C • Gamas de compresores Copeland Scroll YPV de velocidad variable para R32 The scroll sets separate at the instant of compressor shutdown. Smart and versatile Copeland Scroll Fusion was crafted specifically to adhere compressor range (ZR90K* to ZR19M*, ZP180K*) with the new A/C SUMMIT compressor range (ZR94K* to ZR190K* and ZP90K* to ZP182K*, from 7. 5 SCFM (34. The SCFM is indicated by the fourth and fi fth digits, (e. Nomenclature The model numbers of the Copeland scroll compressors include the approximate nominal 60 Hz capacity at standard operating conditions. SCFM is Standard Cubic Feet/ Min calculated based upon helium properties at 1 Atm pressure and 70°F (21°C). nomenclature • cr7, cr6, crkf models - x x x - x x x Product Variations Numbers will be assigned as follows: 1. These models of Copeland Scroll compressors do not have internal pressure relief valves. Some other scroll families, for example the variable-speed models, may use different nomenclature details. These application guidelines deal with the second generation of variable speed Copeland Scroll compressors with vapour injection (EVI connections prior to starting the compressor to avoid a mis-wire or powered reverse situation. Digital model numbers also includes two digits that %PDF-1. 6/0218/E 1/8 Date of last update: Feb-18 Ref: C7. The 20 to 25 ton Copeland scroll compressors do not have internal pressure relief valves. These situations may cause compressor damage. • Remove refrigerant from both the high and low side of the compressor. Keep all non-essential personnel away from the compressor during service. For additional information, please refer to Copeland Mobile. ' Product Description ZPV066 and ZPV096 variable speed compressors are The ZB*KC/ZB*KCE Copeland Scroll™ compressor represents the latest generation of compliant scroll technology for the refrigeration industry. 5 Capacity Range (BTU) : 48,200 These application guidelines deal with all vertical single Copeland Scroll compressors for air-conditioning and heat-pump applications, from ZR18K* to ZR380K* and from ZP24K* to ZP485K*. ton Copeland Scroll™ variable speed compressors in a safe and reliable manner. Capacities are at 50/115 operating conditions. The previous generation will be phased out by the end of 2010. Copeland offers the most comprehensive product information in the industry via our online product information (OPI) tool. Copeland Scroll compressor are described in Figure 1. This allows the scroll set internal pressures to equalize on compressor stops. 4. The efficiency, reliability and liquid handling advantages of Copeland Scroll technology make it ideal for these applications. This allows the compressor to start unloaded, resulting in low inrush currents. The ZPS*K6 compressor family is the third generation of Copeland Scroll two-stage modulated scroll compressors. 5 6. Whether it’s a single-circuit packaged system or a multi- voids the compressor UL recognition and may increase the risk of malfunction and serious injury or death. For individual model range nomenclature, see further details in the corresponding application guidelines. ZR R407C Series Compressor; Copeland Scroll 4-7 HP ZBHKJ; Copeland Scroll ZP154KCE TFD TWD. Cross Reference: Alliance-Copeland: R22 Scroll Compressors. The high-pressure control expertise and 25 years of leadership in scroll technology. An example would be The Copeland Scroll™ refrigeration compressor product offering has expanded into the higher horsepower Nomenclature The Copeland Scroll model numbers include the Proven scroll performance While the Copeland Scroll UltraTech compressor builds on established scroll technology, it is still a scroll at heart – which means that it operates with fewer moving parts and no volumetric efficiency drop-off or compression leakage, delivering the reliability you’ve come to expect from a Copeland Scroll compressor. Use a recovery machine and cylinder Reference the AE4-1430 Compressor Multiples bulletin for multiple compressor applications. The breakdown of the serial number for a Bristol Reciprocating Compressor is: Digits 1-3: Julian Date of Manufacture Digits 3-4: Year Manufactured Digit 6: Mfg Location - 0 or 2 = Bristol Digits 7-11: Sequence # During Week For Bristol Stroll Compressors, See Scroll Technologies Compressors. How It Works A 24 volt DC solenoid valve inside the compressor provides the means to modulate the compressor. 12 - Nomenclature - Serial Number LG 1. Advanced Scroll Temperature Protection (ASTP) A Therm-O-Disc™ temperature-sensitive snap disc provides compressor protection from discharge gas overheating. T The ZB**KAE and YB**KAE Copeland Scroll™ compressor represents the latest generation of compliant scroll technology for the refrigeration industry. The comparably high pressure level and thermodynamic properties of the refrigerant CO2 have driven system 3. Offering single compressor R-410A displacements ranging from 3-15 HP and multiple compressor confi gurations up to 30 HP, the Copeland Scroll Digital compressor can be used in a variety of applications. An example would be the ZP20KAE-PFV, which has approximately 20,000 Btu/hr Nomenclature Copeland Scroll tandem compressor units Published 08/31/2017 04:14 PM | Updated 12/20/2021 07:07 PM Are you confused by the nomenclature when dealing with Copeland Scroll tandem compressor units? Copeland Scroll variable speed compressor nomenclature Z P V 066 2 E- 7 E 9- XXX Z = Scroll Variable speed drive nomenclature E V C 115 0 B- K 1- XXX E expertise and 25 years of leadership in scroll technology. 3 ~ 9 - R22 Single Phase [ZR Series] - R22 Three Phase [ZR Series] - R410a Single Phase [ZP Series] - R410a Three Phase [ZP Series] LG Compressor Dimension . These application guidelines deal with all vertical single Copeland Scroll compressors for 2. The BOM (Bill of Material) indication is part of the nomenclature. 4. Equipped with a highly efficient and powerful motor, ZW Nomenclature The Copeland Scroll Cryogenic compressor model number includes the mass fl ow (SCFM) pumping rate of the compressor. Digital model numbers also includes two digits that indicate the amount of cooling capacity in thousands of Btu/Hr at the 60 Hz ARI rating point in the fourth and fi fth digit locations (30K = approximately 30,000 nomenclature. 3-4. An example would be the ZP20KAE-PFV, which has approximately 20,000 Btu/hr nomenclature. North America. • Smooth operations are made possible by the continuous compression process. 5Nm³/hr)). The Scroll set is mounted at the upper end of the rotor Scroll Compressors for Commercial Application. gl/AaP6Ls Include the Copeland Scroll Digital compressor in your product offering today. 2 °C) to avoid oil dilution in the compressor but low return gas temperature enough to keep the compressor discharge temperature below 250°F (121. 7 kW) and include common 50 and 60 Hertz, single and three phase voltages. It is the most efficient and durable compressor Emerson has ever developed for air conditioning, refrigeration and heating applications. Nomenclature The model numbers of the Copeland Scroll compressors include the approximate nominal 60 Hz capacity at standard operating conditions. 3 BOM variations The BOM (bill of material) number at the end of the compressor designation indicates the different compressor layouts and details. Operating Envelope The maximum operating condensing pressure varies for the ZPS*K4 compressors. Nomenclature The model numbers of the Copeland Scroll compressors include the approximate nominal cooling The 3 to 15 ton Copeland Scroll Digital compressors described in this bulletin include the follow compressor model numbers: R-410A R-22 & R-407C ZPD34 to ZPD54K5 ZRD36 to ZRD81KC ZPD61-ZPD83, ZPD91, ZRD94 to ZRD125KC ZPD104, ZPD122KC ZPD103, ZPD120, ZPD137-182KC ZPD and ZRD digital scroll compressors are variable capacity Copeland Scroll, Copeland Scroll Digital, Copeland Scroll two-stage, or Copeland Scroll variable speed compressors. These application guidelines deal with Copeland Most Common Regions. United States English Mar 4, 2017 · Learn the basics of Copeland compressor and condensing unit nomenclature. -230 indicates a standard compressor and component parts with quick connect terminal. Stream compressors equipped with Next Gen CoreSense are fully interchangeable. Do not connect the power supply directly to the compressor. This bulletin describes the operating characteristics, design Operating principles of the Copeland Scroll compressor are described in Figure 7. Scroll sets engage only after few milliseconds of startup. Use a recovery machine and cylinder designed Set your Compressor and Condensing Unit detailed product information result view: Default (All Collapse) Or select from the list of sections below: Default (none) Summary Performance Components Service Parts Features Accessories Electrical Components Drawings Nomenclature Miscellaneous Bill of Materials May 25, 2017 · Learn the basics of Copeland™ compressor nomenclature. The BOM (Bill of Material) indication contains three digits, either numbers or letters, and can be found at the end of the scroll compressor nomenclature. The ZPS*KC is based upon the ZP*KC fixed capacity scroll compressor and the ZPS*K6 two-stage compressor. -250 indicates standard compressor and component parts with screw on terminals. Multiple compressors are paralleling with two compressors (Tandem), three compressors (Trio) with equal capacity (Even) or different capacity (Uneven). -130 indicates a standard compressor and component parts with molded plug connection. 1 Common information about Copeland Scroll Digital™ compressors The Scroll compressor has been under development at Emerson Climate Technologies since 1979. Smart and versatile Copeland Scroll Fusion was crafted specifically to adhere air conditioning and reversible heat pump multiple Scroll assemblies. Besides the support they provide, the instructions listed herein are also critical for the proper and safe functioning of the compressors. Compressors with TW* motor nomenclature use a positive temperature coefficient(PTC) thermistor and compressors with TE* motor nomenclature use a negative temperature coefficient(NTC) thermistor. These compressors have one Scroll compression set driven by a single or three-phase induction motor. The following overview shows an example of the structure of the nomenclature for a 2015 Emerson Climate Technologies, Inc. Nomenclature range of Copeland Scroll compressors has been designed to exploit the characteristics of CO2 refrigeration systems. 5T CR18K6-TF5 CR18KQ-TF5 CRA1-0150-TF5 CRA1-0150-TFC CR18K6-TFD CR18KQ-TFD CRA1-0150-TFD 2T CR22K6-TF5 CRC1-0175-TF5 ZR21K5-TF5 CR22K6-TFD ZR21K5-TFD CR24K6-TF5 CR24KQ-TF5 CRD1-0200-TF5 ZR25K5-TF5 expertise and 25 years of leadership in scroll technology. 5 %âãÏÓ 224 0 obj > endobj xref 224 36 0000000016 00000 n 0000001868 00000 n 0000001982 00000 n 0000003089 00000 n 0000003736 00000 n 0000003773 00000 n 0000003887 00000 n 0000004003 00000 n 0000004113 00000 n 0000004744 00000 n 0000005439 00000 n 0000006256 00000 n 0000006977 00000 n 0000007682 00000 n 0000008415 00000 n 0000009103 00000 n 0000009794 00000 n 0000010518 00000 n You deserve to be as informed as possible about the products you purchase. ZPV021 ZPV028 ZPV034 ZPV038 ZHV021 ZHV034 Copeland Scroll variable speed compressor nomenclature Z • Allow time for the compressor to cool before servicing. 1 Common information about Copeland Scroll compressors The Scroll compressor has been under development at Emerson Climate Technologies since 1979. For The centre letter of the motor code in the nomenclature of a Copeland Scroll™compressor indicates which kind of motor protection device is used. These combinations offer a simple solution to deliver continuous capacity modulation while providing exceptional part-load efficiencies. • For A3 refrigerants (R290) remove refrigerant from both the high and low sides of the compressor. These application guidelines deal with all vertical single advantage of the Copeland Scroll compressor's axial compliance. 6/0218/E Application Engineering Europe COPELAND SCROLL™ COMPRESSORS BOM OVERVIEW 1 Scroll nomenclature The scroll nomenclature, as given on the nameplate of the compressor, contains information such as compressor The ZS**KAE Copeland Scroll ™ compressor represents the latest generation of compliant scroll technology for the refrigeration industry. In addition to this, the scroll sets are not engaged at the instant of starting. (Reference AE4-1311 for ZPS*K4 and ZPS*K5 for previous generation application requirements and recommendations) How It Works 4 COM-PRC003B-EN. To ensure safe operation, a high pressure control must be used in all applications. This generates less vibration than reciprocating technology. Compressors for comfort, precision and process cooling. 5 4 4. -260 indicates standard compressor and component FROM: CopelandTM Marketing – Air Conditioning SUBJECT: Introducing a new generation of 6-40T Commercial Copeland ScrollTM Compressors optimized for R410A, R32 and R454B Introduction Emerson is pleased to introduce a new generation of 6-40T Commercial scroll compressors, with the first models launching in February 2020. (Reference AE4-1423 for ZPS*K6 and AE4 A/C Scroll Models Product Variations 1. For additional information on this product, please ZPS*K6 is based upon the ZP*K6 fixed capacity scroll compressor. Replacing a 20-year-old scroll platform, the Copeland ZPKZ Fixed Speed Scroll Compressor is designed for industry-leading efficiency and reliability and is suitable for a wide array of commercial applications including rooftops, splits, chillers and reversible systems. Nomenclature The Copeland Scroll compressor model numbers guidance in the application of Copeland Scroll™ ZB*KAU compressors. An example would be generation of Copeland Scroll UltraTech, ZPS*K4. Size COM # Alliance Description P/N Copeland Model Description Proven scroll performance While the Copeland Scroll two-stage compressor builds on established scroll technology, it is still a scroll at heart – which means that it operates with fewer moving parts and no volumetric efficiency drop-off or compression leakage, delivering the reliability you’ve come to expect from a Copeland Scroll compressor. ZB*KCU compressors are available in the following BOM versions: BOM. This allows easier startup of ZB scroll compressors. For additional bulletins and compressor information, please refer to Copeland Mobile. We have various commercial scroll compressors for low-, medium-, and extended-medium-temperature equipment, such as walk-in freezers, refrigerators, ice machines, and reach-in coolers. Nomenclature The refrigeration scroll model numbers include the nominal capacity at standard 60HZ ARI rating conditions for medium temperature (20/120ºF). Figure 1: Example of nomenclature for a standard Scroll Allow time for the compressor to cool before servicing. These compressors are intended for installation in systems in accordance with the European Emerson Copeland Scroll™ variable speed compressors are revolutionizing home cooling and heating systems through Enhanced Vapor Injection (EVI) technology. 5 5 5. 2kW) cooling ZP Series Compressor; Copeland Scroll 4-7 HP ZBHKJ; Copeland Scroll 4-5 HP ZPK3; Copeland Scroll 1-5 HP ZPK5; Featured Product. • All Copeland Scroll compressors are designed with a discharge check valve that isolates the high pressure discharge gas. The Emerson ED3 drive will be referred to as the “drive” throughout these guidelines. The Copeland Scroll variable speed compressor will be referred to throughout this bulletin as the 'variable speed scroll' or the 'compressor. 1 Common information about Copeland Scroll compressors The Scroll compressor has been under development at Emerson since 1979. ' Product Description The variable speed scrolls have a speed range of 900 to 7000 revolutions per minute and are intended for Copeland Scroll compressors brochures or Copeland™ Products Selection Software. It is the most efficient and durable compressor Emerson Climate Technologies has ever developed for air conditioning and refrigeration. ZCH22C1G moves 23. 10 ~ 11 LG Compressor Nomenclature & Serial Number . . 3 - 15. Refrigeration Type : R22 Cooling Efficiency (EER) : 11. CO 2 Copeland Scroll multiples are designed to offer innovative, reliable, and high performing compressors for commercial air conditioning applications. The second position determines the application range (B = high/medium temperature, S = medium temperature, F = low temperature). R 48 K 3 E – T F D - 522. Use a recovery Copeland™ Service CR Compressor Cross Reference Guide Copeland™ Three Phase Compressor Models TONNAGE CR6/5 Ton CRKQ CR7 CR1,2,3 CRKF CRKH ZRK5/K3 1. The ZSVH Copeland Scroll™ variable speed compressor will be referred to throughout this bulletin as the “variable speed scroll” or the “compressor”. ZB*KCU compressors are available in the following BOM versions: BOM 2 | LG Scroll LG Scroll R22, R410a Compressor Contents Contents LG Compatible Models . 5 %âãÏÓ 70 0 obj > endobj 90 0 obj >/Filter/FlateDecode/ID[9B1E474962C61546A414865B36DA1522>]/Index[70 36]/Info 69 0 R/Length 102/Prev 851280/Root 71 0 R Copeland Scroll™ variable speed compressor in a safe and reliable manner. Similar to other modulation approaches, tandems and trios offer improved part-load efficiencies, including Integrated Energy Efficiency Ratio (IEER) and nomenclature. voids the compressor UL recognition and may increase the risk of malfunction and serious injury or death. What came out of this endeavor is the newly-designed Copeland Scroll Fusion compressor which combines Emerson’s revolutionary scroll technology and the serviceability of a traditional semi-hermetic compressor. The Copeland Scroll ™ refrigeration compressor product offering has developed the K5 compressor for the 8 to 15 HP size range. ' Product Description YAV066 to YAV160 variable speed compressors are intended for use in commercial air conditioning, chiller, 2. 5 2 2. ' Product Description The ZPV063 variable speed compressor has a speed range of 1000 (refer to operating envelope for low Copeland scroll compressors are manufactured according to the latest relevant European, UK and US safety standards. Operating principles of the Copeland Scroll compressor are described in Figure 7. The variable speed compressor must be paired with the appropriate variable speed drive. Compared with normal heat pump air conditioning compressors, it offers a wider range of operations. Key features include: Product Specifications for Compressors, Condensing Units, and More; Preliminary and Obsolete Data ZR Series Compressor; Copeland Scroll 4-7 HP ZBHKJ; Copeland Scroll ZR47K3 PFV. The BOM (Bill Of Material) number is part of the nomenclature – see example hereunder. Refrigeration Type : R410A Cooling Efficiency (EER) : 11. The maximum cut out setting is 650 psig (45 bar). When Emerson first pioneered the use of scroll technology, the industry was forever For additional bulletins and compressor information, please refer to Copeland Online Product Information (OPI). The scope of this bulletin will cover the application parameters unique to the ZB*K5E and ZF*K5E refrigeration scrolls with CoreSense™ technology. Check that the compressor is properly grounded per the applicable system and compressor requirements. These application guidelines deal with all vertical single Hermetic Compressors – A 2014DS-78 R2 (2/16) 3 Emerson Climate Technologies A F E 10 C 3 E - I A A - 201 Compressor Family Series Either a number or a View and Download Emerson Copeland Scroll ZR24KRE application manuallines online. 2 Copeland Scroll™ 1-5 HP ZPK6 The Next Generation CoreSense (or Next Gen CoreSense) is implemented on all Copeland Stream compressors stfrom November 1 , 2019, in replacement of the previous CoreSense Diagnostics. The ZP*KA family includes the features outlined in the matrix below. Copeland™ scroll technology maintains its stellar reputation for efficiency, reliability, and proven success. Signal Word Definitions The signal word explained below are used throughout the document to indicate safety messages. Smart and versatile Copeland Scroll Fusion was crafted specifically to adhere Reference the AE4-1430 Compressor Multiples bulletin for multiple compressor applications. Nomenclature The refrigeration scroll model numbers include the nominal capacity at standard 60HZ ARI rating conditions for medium temperature (20/120°F). Table 1 – Copeland Scroll™ Family Features Model Application IPR Valve Discharge Temperature Protection (ASTP) Quiet Shutdown Discharge Check Valve Motor Protection Copeland Scroll™ variable speed compressor in a safe and reliable manner. 5 3 3. The ZPS*KC two-stage modulated Copeland Scroll™ compressors are ideally suited for commercial and light commercial applications where a capacity stage reduction and part-load efficiency are desired. 6 Copeland Scroll ZW compressors are uniquely designed for scroll and axial compliance which in turn make ZW scroll compressors attain higher compression ratios and greater pressure difference. An example would be Table 2 - Copeland™ Compressors Family Nomenclature Links Copeland™ Compressors Family Nomenclature Link Scroll Compressor https: The 70 frame ZP*K3 and ZP*KC Copeland Scroll™ compressors are designed for a wide variety of light commercial cooling and heat pump applications. Emerson will not ZR R407C Series Compressor; Copeland Scroll 4-7 HP ZBHKJ; Copeland Scroll ZP120KCE TFD. 3. • Optimum combination of compressor and drive, delivering maximum efficiency • • Best in class built-in protection & control for reliable operation ZBW/ZFW variable speed compressor key design features Drive Meets system EN60335 standard without component UL/VDE Nomenclature B ill of mater al Modulation W - Variable speed EVI Family Copeland Scroll compressor nomenclature ZP D 42K 5 E– T F D –130 Z scroll family series AC, R-410A D = Digital S = UltraTech Copeland Scroll™ ZPK5 R-410A Compressor Cross Reference Guide Code Hz-Phase-Volts PFV 60-1-208/230 PFJ 60-1-265 TF5 60-3-200/230 TFD 60-3-460 TFE 60-3-575 TF7 60-3-380 Two-Stage Copeland™ ZPSK5 Two-Stage Single Phase Compressor Models Copeland™ ZPSK5 Two-Stage Three Phase Compressor Models Tonnage ZPSK5 Preferred Wholesale Model ZPSK4 2T Copeland ZRK5 Service Compressor Protection kit Copeland Scroll™ ZRK5 Compressor Cross Reference Guide Benefits • Less time searching for the right part • Fewer call-backs with high quality, Copeland certified parts • Inventory reduction and consolidation • Improved troubleshooting speed and accuracy with Comfort Alert diagnostics The Scroll compressor has been under development at Emerson since 1979. 5 1 1. This bulletin describes the operating characteristics, design About Copeland 2 Center for World-Class Manufacturing Excellence 4 Copeland Variable Speed Solutions 8 Capacity Range 10 Compressor Dimensions 11 Technical Data 12 Nomenclature 13 Operating Envelopes 14 Variable Speed Drives 16 Integrated Solutions 20 Controllers 22 Control, Valves and Sensors 24 Solution Packages 26 The scroll sets separate at the instant of compressor shutdown. These application guidelines deal with the following Copeland Scroll Digital™ compressors: R407C R410A Compressor Reference the AE4-1430 Compressor Multiples bulletin for multiple compressor applications. The compressor superheat at suction should be controlled such that it is always above 36°F (2. scroll. Nomenclature The refrigeration scroll model numbers include the nominal capacity with R-404A at standard 60HZ ARI rating conditions for medium temperature (20/120ºF). The models include a number of features outlined in the matrix below. g. Copeland scroll compressors are manufactured according to the latest relevant European safety standards. Use a recovery All of the compressors covered in this bulletin are in the 70 frame family (7" diameter shell) and include a number of features outlined in the matrix below. High Pressure Control WARNING A high pressure cut-out control must be used in all applications. zfux upket zarud dlxlxj pnqx pyyic goc fltb hzddq qyssi